MCA14-MCE14 ELECTRIC SPECIFICATIONS

MCA14 Through-hole MCE14 Through-hole
Range of resistance values* Lin (A) 100Ω ≤ Rn ≤ 5MΩ 100Ω ≤ Rn ≤ 5MΩ
Log (B) Antilog (C) 1 KΩ ≤ Rn ≤ 2M2Ω 1 KΩ ≤ Rn ≤ 2M2Ω
Tolerance Rn < 100Ω: +50%, -30% (out of range)
100Ω ≤ Rn ≤ 100KΩ ±20% ±20%
100K< Rn ≤ 1MΩ: ±20% ±20%
1MΩ < Rn ≤5MΩ: ±30% ±30%
Rn > 5MΩ: +50%, -30% (out of range)
Variation laws Lin (A), Log (B), Antilog (C). Other tapers available on request
Residual resistance Rn ≤ 400Ω ≤ 2Ω; Rn > 400Ω 5*10-3* Rn ≤2Ω
CRV - Contact ResistanceVariation (dynamic) Lin (A) Electrical Angle 220º±20º ≤ 3%Rn.Other tapers, please inquire
CRV - Contact ResistanceVariation (static) Lin (A) Electrical Angle 220º±20º ≤ 5%Rn.Other tapers, please inquire
Maximum power dissipation** at 50ºC at 70º C.
Lin (A) 0.25W 0.7W
Log (B), Antilog (C) 0.13W 0.30W
Maximum voltage Lin (A) 250VDC
Log (B), Antilog (C) 200VDC
Operating temperature -25ºC … +70ºC (up to +120ºC, inquiry) -40ºC … +90ºC (+125ºC, inquiry)
Temperature coefficient 100Ω ≤ Rn ≤ 10KΩ +200/ -300 ppm ±100 ppm
10KΩ < Rn ≤ 5MΩ +200/ -500 ppm ±100 ppm